State-of-the-art Machine Learning MRI Reconstruction in 2020: Results of the Second fastMRI Challenge

Share this post on:

Accelerating MRI scans is one of the principal outstanding problems in the MRI research community. Towards this goal, we hosted the second fastMRI competition targeted towards reconstructing MR images with subsampled k-space data. We provided participants with data from 7,299 clinical brain scans (de-identified via a HIPAA-compliant procedure by NYU Langone Health), holding back the fully-sampled data from 894 of these scans for challenge evaluation purposes. In contrast to the 2019 challenge, we focused our radiologist evaluations on pathological assessment in brain images. We also debuted a new Transfer track that required participants to submit models evaluated on MRI scanners from outside the training set. We received 19 submissions from eight different groups. Results showed one team scoring best in both SSIM scores and qualitative radiologist evaluations. We also performed analysis on alternative metrics to mitigate the effects of background noise and collected feedback from the participants to inform future challenges. Lastly, we identify common failure modes across the submissions, highlighting areas of need for future research in the MRI reconstruction community.

Reference: Mathew J. Muckley, ...,   Z. Ramzi,  P. Ciuciu and J.-L. Starck et al . “State-of-the-art Machine Learning MRI Reconstruction in 2020: Results of the Second fastMRI Challenge.

This paper presents the results of the fastMRI 2020 challenge, where our team finished 2nd in the 4x and 8x supervised tracks.
It is currently being submitted to IEEE TMI.

Share this post on: